Fire sprinkler floor control valves.
Sprinkler floor control valve assembly.
Series 747m firelock commercial zone control riser module features a cast body with shut off valve test and drain valve combination and different sizes flow switch and a pressure gauge sizes from 1 6 dn32 dn150.
They are assembled on fire pipeline to separates the fire area into small distribution zone for indication and control.
See full size image.
Svc 1306 recessed 30 x 40 x 10.
Cancer and reproductive harm.
Signal butterfly valve waterflow indicator pressure gauge and test drain valve.
Valve floor control valve accessible nfpa 13 2007 a 8 16 1 1 1 electrically supervised or locked nfpa 25 2014 13 3 1 4 signage must be provided nfpa 25 2014 13 3 1 tested.
Cancer and reproductive harm www p65warnings ca gov.
Sprinkler control assembly fire sprinkler floor control valves.
Section 8 2 1 limits the system size to any one floor to the stated maximum but 8 2 4 3 refers to a system where the total area of all floors combined does not exceed the maximum area allowed by 8 2 1.
Riserpack floor control assemblies meet the requirements of nfpa 13d nfpa 13r and nfpa 13 for wet fire sprinkler systems and can be assembled with additional features to meet.
In rack fire sprinkler solutions.
So if you have a riser feeding several floors and the total area of those floors exceeds the maximum allowed for a single floor then each floor has to have a control valve.
Because of fire sprinkler or test valve activation the indicator detects water flow and transmits signal to control system.
Annually nfpa 25 2014 section 13 3 3 1 waterflow switch.
Fca floor control assembly.
Fca floor control assembly.
Valve sprinkler valve control cabinet.
Provided to permit exact orifice size of sprinkler for waterflow switch testing.
1 2 2 section 8 16 1 5 2 the floor control valve check valve main drain valve and flow switch required by 8 16 1 6 3 shall not be required where sprinklers on the top level of a multistory building are supplied by piping on the floor below.
Easypac floor control assemblies include pressure gauges potter flow switches 3 way gauge control valve and appropriate drain valve.
The model 8000 riserpack floor assembly includes a pressure gauge water flow switch inspectorstest and drain valve.
For further assistance viking s easypac quick reference guide highlights the entire line of easypac riser assemblies.
Easypac assemblies are available in pipe sizes from 1 1 4 to 2 1 2 dn32 to dn60 and are made with fabricated steel bodies.
Kres kfr fusible link sprinklers.